JX 2300   Download documents

 

JX 2300 is designed to be used in SFLS and/or REILS systems, as well as ODALS and Heliport approaches.

 

User manual (until 2011)

User manual (from 2011)

Wiring manual

Trouble shooting

 

Energy per flash :
Flash period :
Flash interval :
Optional brilliance selection :
Brilliance selector voltage :
Alarm reporting :


Working voltage :
Consumption :
Power factor :

Ambiant temperature rating :


External dimensions :
Weight :

  60 J
0,5 s or 1 s
14 ms, 67 ms, 267 ms
100% (day mode), 10% (crepuscular mode), 3% (night mode)
24 V DC or 48 V DC
via pulses on a DC current loop. These pulses have to be managed by an automat.
On simple systems (i.e. REILS only) a relay switches on when alarm occurs on one supply box.

230 V AC 50/60 Hz +/- 10% (110V AC 60 Hz on demand)
less than 200 W
better than 0,95

-25 C to + 55 C (an optional heater resistor can be mounted on demand when moisture level is particularly hight or external temperature particularly low.)
IP 55 cabinet

680 mm x 435 mm x 255 mm
20 kg